Chapter 2: Caddx Panels (done) This chapter contains everything required to program FINMON GSM COMMUNICATORS onto the mainline Caddx Panels. An important note, the miAlarm app does NOT work on the Caddx panels however reporting works via the Dialler. Caddx Standard Dialler Programming Standard Caddx panels connected via Tip & Ring Location Programming Location 0 Segment 1 = 13 (force dial) Segment 2 = 15 (Tone dialling) Segment 3 to 9 = 5555555 (Tel number) Location 1 Segment 1 to 4 = [account code] Location 2 Enter 1 for Contact ID On older panels: Enter 13 Partition Account Codes If using multiple partitions, program account codes for each: Location 89 - Partition 2 account code Location 92 - Partition 3 account code Location 95 - Partition 4 account code Important Notes Force dial (segment 1 = 13) is critical for Caddx panels Always verify tone dialling is enabled (segment 2 = 15) Test each partition if multiple partitions are programmed Older panels may require "13" in Location 2 instead of "1" Caddx NX Dialler Programming Caddx NX (NX4 & NX8) series panels connected via Tip & Ring Location Programming Location 0 Segment 1 = 13 (force dial) Segment 2 = 15 (Tone dialling) Segment 3 to 9 = 5555555 (Tel number) Location 1 Segment 1 to 4 = [account code] Location 2 Enter 1 for Contact ID Location 4 LED 2 ON for openings/closings Partition Account Codes If using multiple partitions: Location 89 - Partition 2 account code Location 92 - Partition 3 account code Location 95 - Partition 4 account code Differences from Standard Caddx Location 4 specifically controls opening/closing reports More reliable communication than older Caddx models Troubleshooting Tips If openings/closings aren't reporting, verify Location 4 LED 2 is ON Ensure all partition account codes are programmed if using partitions Force dial is still required (Location 0, Segment 1 = 13)