Paradox MG5050, SP6000 & SP65 Dialler Programming (done)

Tested on Plus range version 1.30


Enabling the Dialer

The status light on panel will be solid when dialling. If not dialling, check:

Section 800

Section 802

Section 803

Section 805


Dialler Programming

Section 810

Section 811

Section 812

Section 815

Section 817


Opening/Closing Reports

If closings work but not openings:

Section 801


Troubleshooting Tips

  1. Panel won't send despite correct programming:

    • Rarely, a default may be needed
    • Power down, default, reprogram
  2. Account number issues:

    • MUST be entered at both 811 and 812
    • With LED keypad: type account code twice at loc 811
  3. PGM trigger issues:

    • Jumper on motherboard above PGMs sets positive trigger
    • One model only sets one PGM as positive (not both)
    • Paradox fixing in next PCB version

Clear Event Buffer

For 5050 and 6000:

  1. Enter programming mode
  2. Press Stay key once
  3. Press Clear key once
  4. Power panel down
  5. Power up and send signals

For SP65:


Revision #5
Created 30 July 2026 09:30:03 by Jonathan Cox
Updated 15 October 2026 07:18:27 by Jonathan Cox