Paradox MG5050, SP6000 & SP65 Dialler Programming (done) Tested on Plus range version 1.30 Enabling the Dialer The status light on panel will be solid when dialling. If not dialling, check: Section 800 Option 8 must be OFF Options 4, 5, 6, 7 must be ON Section 802 Options 1, 2, 5, 6 must be ON Section 803 Options 1, 2, 5, 6 must be ON Section 805 Option 2 must be ON Dialler Programming Section 810 Select 44 for Contact ID Section 811 Account number for partition 1 Section 812 Account number for partition 2 Section 815 Enter 5555555 Section 817 Enter 5555555 Opening/Closing Reports If closings work but not openings: Section 801 All options must be OFF Troubleshooting Tips Panel won't send despite correct programming: Rarely, a default may be needed Power down, default, reprogram Account number issues: MUST be entered at both 811 and 812 With LED keypad: type account code twice at loc 811 PGM trigger issues: Jumper on motherboard above PGMs sets positive trigger One model only sets one PGM as positive (not both) Paradox fixing in next PCB version Clear Event Buffer For 5050 and 6000: Enter programming mode Press Stay key once Press Clear key once Power panel down Power up and send signals For SP65: Press Power button → Installer code → Memory → 9 → Enter key