# Texecom 412/816/832 Serial Programming (done)

Standard Texecom panels with **red serial cable**

---

#### Version Information

**Texecom 412/816:**
- Known working app versions: V16.13

**Texecom 832:**
- Known working versions: v13, v14 (E)

**Note:** Texecom Elite panels are NOT supported on app, but work with serial for CID

---

#### Basic Programming

**Access Programming:**
- Installer code + Menu + 9
- Default installer code: **1234**


#### Texecom 412 Serial Specific

*Known working app version: V14*

**Location 70**
- Switch ON LEDs 1, 2, and 8 only
- Press ARM button

**Additional for Serial:**
- **71/8** = Switch ON 8
- **76/5** = **3** (com IP on Comm 1)
  
**OR** (NOT BOTH)
- **76/9** = **3** (com IP on Comm 2)

---

#### Converting from Serial to Tip & Ring

If panel was previously on serial and now using Tip & Ring:
- **71/8** = **0**
- **76/5** = **0**

---

#### Special Notes

**Texecom 816:**
- Serial cable connection must be a Texecom GSM type