# Chapter 1: Getting Started

# General FINMON Programming

This page covers the essential programming requirements for all Finmon radio installations.

---

#### Required Programming Steps

The following must be programmed for the Finmon radio to work via the dialler correctly:

1. **Account Code**
   - Four digit code as required by control room
   - Must be inserted in all required locations (some panels need it in multiple places)
   - For six digit fields: program the four digits followed by FF (e.g., 1234FF)

2. **Telephone Number**
   - Program '5555555' in both primary and secondary locations
   - Must be exactly seven 5's

3. **Communication Format**
   - Contact ID must be enabled
   - This is the standard format for all installations

4. **Dial Attempts**
   - Minimum of 6 attempts required

5. **Dial Timeout**
   - For kiss-on (if applicable): minimum 60 seconds
   - If no timeout available, ensure attempts cover:
     - 90 seconds for server send
     - Additional 90 seconds for direct send
     - SMS send time (if enabled)
   - **Note:** SMS limit is 20 free messages per unit per month

6. **Dialing Method**
   - Tone dialling must be enabled (usually default)
   - Do not use pulse dialling

7. **Special Requirements**
   - Forced dialling must be enabled (mostly for Caddx panels)

---

#### Important Notes

- Always verify all settings before leaving site
- Test communication after programming
- Document any deviations from standard programming

# Trigger Inputs Z1-4 on Transmitter

This page covers the configuration of direct trigger inputs on the Finmon transmitter.

---

#### Default Configuration

**Factory Default Account Code:** 9998

When a transmitter is connected to a panel via serial/dialler:
- The panel will automatically update the radio with its account code on first signal
- If the account code is changed on the panel, it will update the radio again

---

#### Direct Connection to Z1-4

When connecting directly to trigger inputs (not through a panel):

1. **Account Code Programming**
   - Must be set by dialling into the radio over the internet
   - Use Finmon website: www.finmon.co.za
   - **REFER TO YOUR FINMON CONSULTANT OR CONTROL ROOM**

2. **Voltage Requirements**
   - The radio requires a positive 12v trip on any of the triggers.
   - Ensure clean, stable 12v signal

---

#### Default Trigger Assignments

| Input | Default Function |
|-------|-----------------|
| **Z1** | Panic |
| **Z2** | Burglary |
| **Z3** | Open by user / Close by User |
| **Z4** | AC Failure |

---

#### Reprogramming Triggers

The trigger inputs can be reprogrammed for any Contact ID reporting code:
- Examples: supervisor on site, pump failure, temperature alarm
- Access required via Finmon website
- Contact Finmon support for custom programming

---

#### Wiring Notes

- Use appropriate gauge wire for 12v signals
- Keep wiring runs as short as practical
- Avoid running trigger wires parallel to AC power
- Use shielded cable in high-interference environments