# Chapter 4: IDS Panels

# IDS805 Programming

IDS805 panels with **grey serial cable** on external serial connector

---

#### Basic Programming

**Locations 43 to 46**
- Enter **[Account code]**

**Location 47**
- Enter **6** (Contact ID)

**Locations 48 to 54**
- Enter **5555555**

**Location 151**
- Default is 4 dial attempts
- Enter **0** to disable the dialer

---

#### Important Notes

- Tone and force dialling are enabled by default
- **LTE GSM must be powered directly from battery**
- Do not power from panel auxiliary output

---

#### App Configuration

For mobile app connectivity:

**Requirements:**
- App version **v4.37** or latest **vE4.xx**
- Serial Port must be set to **Orisec/IDS805**
- Requires a **VALID user code**

---

#### Troubleshooting

- If no communication, verify power is from battery
- Test with known working user code

# IDS806 Programming

IDS806 panels with **red serial cable**

---

#### Basic Programming

**Locations 43 to 46**
- Enter **[Account code]**

**Location 47**
- Enter **6** (Contact ID)

**Locations 48 to 54**
- Enter **5555555**

**Location 196**
- Must be **000000**
- Critical for proper operation

---

#### Installation Procedure

**Important:** Follow this exact sequence:

1. Ensure panel power is **OFF**
2. Connect serial port only (no panel power)
3. Power up the panel
4. Serial port will be automatically detected

---

#### Tested Versions

Successfully tested on firmware versions:
- 1.12
- 1.13
- 1.14
- 1.15
- 1.88

---

#### Critical Notes

- Location 196 must be all zeros
- Panel reboot required after serial connection
- Red serial cable indicates IDS806 compatibility

# IDS816 Programming

IDS816 panel programming locations

---

#### Basic Programming

**Location 111**
- LED 1 **ON**
- All other LEDs **OFF**

**Location 116**
- Enter **5** for Contact ID

**Location 121**
- Enter **5555555**

**Location 128 Sub 2**
- Enter **[Account code]**

---

#### Programming Tips

- Ensure only LED 1 is on in location 111
- Double-check sublocation 2 for account code
- Test communication after programming

# IDS X64 Programming

Complete guide for all X64 variants

---

#### Basic Programming (All Versions)

**Location 41**
- Default setting usually fine
- Set to **5** for Contact ID on Telephone Number 1

**Location 46**
- Subloc 1 (LED 1): **ON** for Tone dialling
- Subloc 2 (LED 2): **OFF**
- Subloc 3 (LED 3): **OFF**

**Location 47**
- Set to **6**

**Location 51**
- Enter **5555555** (seven 5's)

**Location 61-68** (Account Codes)
- Loc 61: Partition 1 account code (4 digits)
- Loc 62: Partition 2 account code
- Loc 63-68: Partitions 3-8 account codes

**Location 71 (72 = P2 -> 78 = P8)**
- Serial account code (same as partition account code)

**Location 196**
- Must be **000000**

**Location 501-564**
- Option 3 must be set to Yes

**Enable User Code Bypassing**
Hold [ * ] → beep → [MASTER CODE] [ * ] [ 1 ] [ 0 ] [ * ] [USER CODE] [ * ] [BITMAP] [ * ] [ # ]

Bitmap(Option 8) Zone Bypass Enable
MUST be set to Yes

---

#### Open/Close Reporting by User

##### For X64 Older than 2017

**Programming Sequence:**
Hold [ * ] → beep → [ MASTER CODE ] [ * ] [ 1 ] [ 4 ] [ * ] [ USER CODE ] [ * ] [ BITMAP ] [ * ] [ # ]

**Enable User Reporting Codes:**

| Subloc/LED | Default | Action |
|------------|---------|--------|
| 1 | OFF | Set ON to enable close reporting |
| 2 | OFF | Set ON to enable stay close reporting |
| 3 | OFF | Set ON to enable open reporting |
| 4 | OFF | Set ON to enable siren cancel reporting |

**Important:** Must be repeated for EACH user requiring open/close reporting!

##### For X64 New (2017 onwards)

1. Enter Installer Mode
2. Go to Partition Arm Options (Locations 211-218)
3. Enable option 16 (Open/Closing User Reporting), this option is global for all users in the partition.

---

#### Arm Without User Code Reporting

For quick-arm and key-switch arming:

**Locations 581-588** (Split Reporting Data)
- Subloc 7: Set **ON** to enable "Armed without user code" reporting
- Location 581 for Partition 1
- Location 582 for Partition 2
- Locations 583-588 for Partitions 3-8

---

#### Serial/App Programming

**Requirements:**
- Panel firmware: V2.80 or above
- GSM firmware: V4.51 or above **OR** E4.19
- Draw power from Aux 12V, **NOT** from serial cable

**Programming:**
- Loc 40: Ensure value **5** (CID) is programmed
- Loc 61: Account code required
- Loc 196: Must be **000000**

**24V Version Additional:**
- Loc 71: Account code required

---

#### Troubleshooting

- If you can connect but get Bypassed zones and are unable to do anything: Check Loc 196 = 000000
- After changing Loc 196: Remove panel from app and re-add
- Cannot control panel: Verify user code
- Connection issues: Check power source (must be Aux 12V)