Chapter 7: Other Panels

Orisec Configuration

Orisec panels support both Tip/Ring and Com Port connections


Orisec Tip/Ring Configuration

  1. Enter Installer Code
  2. Select Programming Menu → Tick/Enter
  3. Go to ARC Set up
  4. Phone Number: 555 5555
  5. Account Number: As supplied by control room/software
  6. Protocol: Contact ID
  7. Dial Seq: 1
  8. Any issues with not sending - RESTART PANEL

Orisec Com Port Configuration

  1. Enter Installer Code
  2. Select Programming Menu → Tick/Enter
  3. Com Port Setup → Tick/Enter
  4. Select Com Port number 2
  5. Set mode to FINMON (Required for app)
  6. Hold Tick to go back
  7. Go to ARC Set up
  8. Phone Number: F555 5555 (Note the 'F' prefix)
  9. Account Number: As supplied by control room/software
  10. Protocol: Contact ID
  11. Dial Seq: 6
  12. Any issues with not sending - RESTART PANEL

App Configuration

Requirements:


Critical Notes

IF YOU AREN'T GETTING SIGNALS OUT:


Risco Configuration

Complete programming guide for Risco panels


Accessing Programming

  1. Press MENU BUTTON
  2. Enter INSTALLER CODE (Default: 1111)
  3. Navigate to "PROGRAMMING" → ENTER
  4. Navigate to "COMMUNICATION" → ENTER

Monitoring Station Setup

Navigate to "MONITORING STATION (MS)" → ENTER
Navigate to "MONITORING STATION 1 (MS 1)" → ENTER

Configure the following:


Timer Configuration

Navigate to "TIMERS":


Periodic Test Setup

Navigate to "PERIODIC TEST":


Report Split Configuration

Navigate to "REPORT SPLIT":


Cloud Settings

Back to main COMMUNICATION menu
Navigate to "CLOUD":


Exit Programming

  1. Press MENU
  2. Press MENU
  3. Press MENU, 0, ENTER to exit