IDS X64 Programming

Complete guide for all X64 variants


Basic Programming (All Versions)

Location 41

Location 46

Location 47

Location 51

Location 61-68 (Account Codes)

Location 71 (72 = P2 -> 78 = P8)

Location 196

Location 501-564

Enable User Code Bypassing Hold [ * ] → beep → [MASTER CODE] [ * ] [ 1 ] [ 0 ] [ * ] [USER CODE] [ * ] [BITMAP] [ * ] [ # ]

Bitmap(Option 8) Zone Bypass Enable MUST be set to Yes


Open/Close Reporting by User

For X64 Older than 2017

Programming Sequence: Hold [ * ] → beep → [ MASTER CODE ] [ * ] [ 1 ] [ 4 ] [ * ] [ USER CODE ] [ * ] [ BITMAP ] [ * ] [ # ]

Enable User Reporting Codes:

Subloc/LED Default Action
1 OFF Set ON to enable close reporting
2 OFF Set ON to enable stay close reporting
3 OFF Set ON to enable open reporting
4 OFF Set ON to enable siren cancel reporting

Important: Must be repeated for EACH user requiring open/close reporting!

For X64 New (2017 onwards)
  1. Enter Installer Mode
  2. Go to Partition Arm Options (Locations 211-218)
  3. Enable option 16 (Open/Closing User Reporting), this option is global for all users in the partition.

Arm Without User Code Reporting

For quick-arm and key-switch arming:

Locations 581-588 (Split Reporting Data)


Serial/App Programming

Requirements:

Programming:

24V Version Additional:


Troubleshooting


Revision #8
Created 10 June 2025 12:33:46 by Calvin van Wieringen
Updated 18 December 2025 07:55:09 by Jonathan Cox