Paradox Evo 192 Dialler Programming sections for the Evo dialler Basic Dialler Setup Section 3036 Option 3 must be ON to enable the dialler Section 3061-3068 (Account Codes) 3061: Partition 1 account code 3062: Partition 2 account code Section 3070 (Format) Enter 4 x 5 for Contact ID Section 3071 (Telephone Number) Enter 5555555 Event Reporting Configuration Sections 3127 to 3829 Check partition options for event call directions These sections tell the panel what events need to be reported Section 4031 Enable all reporting codes for Contact ID Important Programming Tips After all programming: REBOOT the panel - Critical step! Disable the dialer module Re-enable the dialer module, This clears the module for correct dialling. Account Code Rules: NEVER use account codes starting with "0" (e.g., 0001) Use 1001 instead Can use hex A: 1AA1 (press "stay" button for hex A) Troubleshooting If panel won't communicate after programming, always reboot Disable/re-enable dialer module if issues persist