Paradox MG5050 and SP6000 Programming Tested on Plus range version 1.30 Basic Programming Section 810 Select 44 for Contact ID Section 811 Account number for partition 1 Section 812 Account number for partition 2 Section 815 Enter 5555555 Section 817 Enter 5555555 Enabling the Dialer The status light on panel will be solid when dialling. If not dialling, check: Section 800 Option 8 must be OFF Options 4, 5, 6, 7 must be ON Section 802 Options 1, 2, 5, 6 must be ON Section 803 Options 1, 2, 5, 6 must be ON Section 805 Option 2 must be ON Opening/Closing Reports If closings work but not openings: Section 801 All options must be OFF Babyware Programming If using Babyware, these are MANDATORY : Section 910 Must be cleared using sleep button (once per digit) Section 911 Must be cleared using sleep button (once per digit) Troubleshooting Tips Panel won't send despite correct programming: Rarely, a default may be needed Power down, default, reprogram Account number issues: MUST be entered at both 811 and 812 With LED keypad: type account code twice at loc 811 PGM trigger issues: Jumper on motherboard above PGMs sets positive trigger One model only sets one PGM as positive (not both) Paradox fixing in next PCB version 6500 Panel on serial: Does not send account code Only sends signal ONCE Clear Event Buffer For 5050 and 6000: Enter programming mode Press Stay key once Press Clear key once Power panel down Power up and send signals For SP65: Press Power button → Installer code → Memory → 9 → Enter key