# Wireless Devices

*Requires Software version 6.64 (can be checked on the website)*

---

#### Programming

**Location 409** - Serial Port Type
- Input a value of **2** for mi64 Wireless Devices

**Location 200** - Add wireless device
- Input zone number then [*] and hold down the LED on the wireless device until keypad beeps.

**Location 454** - Remove wireless device
- Enter zone number and then [*] to remove the device attached to that zone.

**Location 0** - Remove **ALL** wireless device
- Enter value of **6** and then [*] to remove all the wireless mi64 devices from the panel.
  
---

#### Notes

- Devices are pinged every 17hours to confirm they are alive.
- Devices are polled for battery life every 17hrs.
- Tamper Switch is held down by the bracket on the passive not actually the back of the passive.