The **miPanic** is a versatile security system featuring 4 supervised zones and support for up to 64 user codes or remotes via a built-in receiver.

---

## 1. System Overview

- **Zones:** 4 Supervised zones (Requires $3.3k\\Omega$ End-of-Line resistors).
- **Capacity:** 64 User codes and/or remotes.
- **PGM Output (ARM LED Mode):**
    - **Solid:** System Armed.
    - **Off:** System Disarmed.
    - **Flashing:** Alarm has been triggered.
    - **Flickering:** Force armed (armed while a zone was open).
    - **Zone Logic:** If armed with an open zone, that zone is ignored until it closes, then it becomes active.

---

## 2. Programming: No Keypad (Jumper Method)

To program using the jumpers on the board:

1. Set the jumpers to the desired configuration (see table below).
2. Hold the **Reset** button down.
3. Connect power to the board.
4. Release the **Reset** button once **LED 1** flashes briefly.

### Configuration Modes

<table id="bkmrk-setup-type-zone-logi"><thead><tr><th align="left">Setup Type</th><th align="left">Zone Logic</th></tr></thead><tbody><tr><td align="left">**Panic Setup**</td><td align="left">All zones function as Panic zones.</td></tr><tr><td align="left">**Mini Alarm**</td><td align="left">Zones 1-3: Burglary; Zone 4: Panic.</td></tr><tr><td align="left">**Mini Alarm (Delay)**</td><td align="left">Zone 1: Entry/Exit Delay; Zones 2-3: Burglary; Zone 4: Keyswitch.</td></tr></tbody></table>

### Remote Management (Jumper Method)

- **Add Remotes:** Set jumpers to "Add" position $\\rightarrow$ Hold Reset until LED 1 flashes $\\rightarrow$ Press any remote button (Siren will toot).
- **Delete All Remotes:** Set jumpers to "Delete All" position $\\rightarrow$ Hold Reset until LED 1 flashes.
- **Delete Individual Remote:** Set jumpers to "Delete Individual" position $\\rightarrow$ Hold Reset until LED 1 flashes $\\rightarrow$ Press a button on the specific remote to remove it.

---

## 3. Programming: With Keypad

### Installer Mode

Access by entering: `[Installer Code] (Default 9999)` + `*`

<table id="bkmrk-location-description"><thead><tr><th align="left">Location</th><th align="left">Description</th><th align="left">Details</th></tr></thead><tbody><tr><td align="left">0</td><td align="left">**Default Options**</td><td align="left">0=All, 1=Master Code (1234), 2=Users, 3=Download Code, 4=WiFi, 5=Wireless Sensors.</td></tr><tr><td align="left">**1**</td><td align="left">**Panel Setup**</td><td align="left">1=Panic, 2=Mini Alarm, 3=Mini Alarm with Delay.</td></tr><tr><td align="left">**2**</td><td align="left">**Account Code**</td><td align="left">Enter 4-digit code for reporting.</td></tr><tr><td align="left">**3**</td><td align="left">**Installer Code**</td><td align="left">Enter new 4-digit installer code.</td></tr><tr><td align="left">**4**</td><td align="left">**Enroll Wireless**</td><td align="left">(Firmware E3.04 and up).</td></tr></tbody></table>

### User Code Programming

Access by entering: `Alt` + `*` + `[Master Code] (Default 1234)` + `*`

<table id="bkmrk-loc-action-instructi"><thead><tr><th align="left">Loc</th><th align="left">Action</th><th align="left">Instruction</th></tr></thead><tbody><tr><td align="left">**1**</td><td align="left">**Add User**</td><td align="left">Enter 4-digit code + `*`. Press remote button to link, or `#` to skip.</td></tr><tr><td align="left">**2**</td><td align="left">**Change User**</td><td align="left">Enter existing code + `*`. Enter new code or press remote button.</td></tr><tr><td align="left">**3**</td><td align="left">**Delete User**</td><td align="left">Enter 4-digit code + `*` to remove both code and remote.</td></tr><tr><td align="left">**4**</td><td align="left">**Delete by ID**</td><td align="left">Enter User Number (e.g., 1 for Master) + `*`.</td></tr><tr><td align="left">**5**</td><td align="left">**Add Remote Only**</td><td align="left">Press remote button to enroll. Repeat for more, press `#` to exit.</td></tr></tbody></table>

---

## 4. User Operations

### Bypassing Zones

1. Press `Alt` + `9`.
2. Press the **Zone Number** followed by `*` to toggle bypass.
3. Press `#` to exit. 
    - *Note: Panic and Keyswitch zones cannot be bypassed.*

### Trouble Conditions

If the **Power LED** is flashing **Red**, press `Alt` + `7`. The Zone LEDs will indicate the specific issue:

<table id="bkmrk-led-description-led-"><thead><tr><th align="left">LED</th><th align="left">Description</th><th align="left">LED</th><th align="left">Description</th></tr></thead><tbody><tr><td align="left">**1**</td><td align="left">Siren Tamper</td><td align="left">**5**</td><td align="left">Comms Fail</td></tr><tr><td align="left">**2**</td><td align="left">Aux 12V Fuse</td><td align="left">**6**</td><td align="left">Low Battery</td></tr><tr><td align="left">**3**</td><td align="left">Box Tamper</td><td align="left">**7**</td><td align="left">Network Problem</td></tr><tr><td align="left">**4**</td><td align="left">AC Fail</td><td align="left"></td><td align="left"></td></tr></tbody></table>

---