miPanic Quick Reference Guide

The miPanic is a versatile security system featuring 4 supervised zones and support for up to 64 user codes or remotes via a built-in receiver.


1. System Overview


2. Programming: No Keypad (Jumper Method)

To program using the jumpers on the board:

  1. Set the jumpers to the desired configuration (see table below).
  2. Hold the Reset button down.
  3. Connect power to the board.
  4. Release the Reset button once LED 1 flashes briefly.

Configuration Modes

Setup Type Zone Logic
Panic Setup All zones function as Panic zones.
Mini Alarm Zones 1-3: Burglary; Zone 4: Panic.
Mini Alarm (Delay) Zone 1: Entry/Exit Delay; Zones 2-3: Burglary; Zone 4: Keyswitch.

Remote Management (Jumper Method)


3. Programming: With Keypad

Installer Mode

Access by entering: [Installer Code] (Default 9999) + *

Location Description Details
0 Default Options 0=All, 1=Master Code (1234), 2=Users, 3=Download Code, 4=WiFi, 5=Wireless Sensors.
1 Panel Setup 1=Panic, 2=Mini Alarm, 3=Mini Alarm with Delay.
2 Account Code Enter 4-digit code for reporting.
3 Installer Code Enter new 4-digit installer code.
4 Enroll Wireless (Firmware E3.04 and up).

User Code Programming

Access by entering: Alt + * + [Master Code] (Default 1234) + *

Loc Action Instruction
1 Add User Enter 4-digit code + *. Press remote button to link, or # to skip.
2 Change User Enter existing code + *. Enter new code or press remote button.
3 Delete User Enter 4-digit code + * to remove both code and remote.
4 Delete by ID Enter User Number (e.g., 1 for Master) + *.
5 Add Remote Only Press remote button to enroll. Repeat for more, press # to exit.

4. User Operations

Bypassing Zones

  1. Press Alt + 9.
  2. Press the Zone Number followed by * to toggle bypass.
  3. Press # to exit.
    • Note: Panic and Keyswitch zones cannot be bypassed.

Trouble Conditions

If the Power LED is flashing Red, press Alt + 7. The Zone LEDs will indicate the specific issue:

LED Description LED Description
1 Siren Tamper 5 Comms Fail
2 Aux 12V Fuse 6 Low Battery
3 Box Tamper 7 Network Problem
4 AC Fail