# New Page

# miPanic Quick Reference Guide

The **miPanic** is a versatile security system featuring 4 supervised zones and support for up to 64 user codes or remotes via a built-in receiver.

---

## 1. System Overview
* **Zones:** 4 Supervised zones (Requires $3.3k\Omega$ End-of-Line resistors).
* **Capacity:** 64 User codes and/or remotes.
* **PGM Output (ARM LED Mode):**
    * **Solid:** System Armed.
    * **Off:** System Disarmed.
    * **Flashing:** Alarm has been triggered.
    * **Flickering:** Force armed (armed while a zone was open).
    * **Zone Logic:** If armed with an open zone, that zone is ignored until it closes, then it becomes active.

---

## 2. Programming: No Keypad (Jumper Method)
To program using the jumpers on the board:
1.  Set the jumpers to the desired configuration (see table below).
2.  Hold the **Reset** button down.
3.  Connect power to the board.
4.  Release the **Reset** button once **LED 1** flashes briefly.

### Configuration Modes
| Setup Type | Zone Logic |
| :--- | :--- |
| **Panic Setup** | All zones function as Panic zones. |
| **Mini Alarm** | Zones 1-3: Burglary; Zone 4: Panic. |
| **Mini Alarm (Delay)** | Zone 1: Entry/Exit Delay; Zones 2-3: Burglary; Zone 4: Keyswitch. |

### Remote Management (Jumper Method)
* **Add Remotes:** Set jumpers to "Add" position $\rightarrow$ Hold Reset until LED 1 flashes $\rightarrow$ Press any remote button (Siren will toot).
* **Delete All Remotes:** Set jumpers to "Delete All" position $\rightarrow$ Hold Reset until LED 1 flashes.
* **Delete Individual Remote:** Set jumpers to "Delete Individual" position $\rightarrow$ Hold Reset until LED 1 flashes $\rightarrow$ Press a button on the specific remote to remove it.

---

## 3. Programming: With Keypad
### Installer Mode
Access by entering: `[Installer Code] (Default 9999)` + `*`

| Location | Description | Details |
| :--- | :--- | :--- |
| **0** | **Default Options** | 0=All, 1=Master Code (1234), 2=Users, 3=Download Code, 4=WiFi, 5=Wireless Sensors. |
| **1** | **Panel Setup** | 1=Panic, 2=Mini Alarm, 3=Mini Alarm with Delay. |
| **2** | **Account Code** | Enter 4-digit code for reporting. |
| **3** | **Installer Code** | Enter new 4-digit installer code. |
| **4** | **Enroll Wireless** | (Firmware E3.04 and up). |

### User Code Programming
Access by entering: `Alt` + `*` + `[Master Code] (Default 1234)` + `*`

| Loc | Action | Instruction |
| :--- | :--- | :--- |
| **1** | **Add User** | Enter 4-digit code + `*`. Press remote button to link, or `#` to skip. |
| **2** | **Change User** | Enter existing code + `*`. Enter new code or press remote button. |
| **3** | **Delete User** | Enter 4-digit code + `*` to remove both code and remote. |
| **4** | **Delete by ID** | Enter User Number (e.g., 1 for Master) + `*`. |
| **5** | **Add Remote Only**| Press remote button to enroll. Repeat for more, press `#` to exit. |

---

## 4. User Operations

### Bypassing Zones
1.  Press `Alt` + `9`.
2.  Press the **Zone Number** followed by `*` to toggle bypass.
3.  Press `#` to exit.
    * *Note: Panic and Keyswitch zones cannot be bypassed.*

### Trouble Conditions
If the **Power LED** is flashing **Red**, press `Alt` + `7`. The Zone LEDs will indicate the specific issue:

| LED | Description | LED | Description |
| :--- | :--- | :--- | :--- |
| **1** | Siren Tamper | **5** | Comms Fail |
| **2** | Aux 12V Fuse | **6** | Low Battery |
| **3** | Box Tamper | **7** | Network Problem |
| **4** | AC Fail | | |

---