IDS805 Programming
IDS805 panels with grey serial cable on external serial connector Basic Programming Locations 43 to 46 Enter [Account code] Location 47 Enter 6 (Contact ID) Locations 48 to 54 Enter 5555555 Location 151 Default is 4 dial attempts Enter 0 to disable the...
IDS806 Programming
IDS806 panels with red serial cable Basic Programming Locations 43 to 46 Enter [Account code] Location 47 Enter 6 (Contact ID) Locations 48 to 54 Enter 5555555 Location 196 Must be 000000 Critical for proper operation Installation Procedure Important...
IDS816 Programming
IDS816 panel programming locations Basic Programming Location 111 LED 1 ON All other LEDs OFF Location 116 Enter 5 for Contact ID Location 121 Enter 5555555 Location 128 Sub 2 Enter [Account code] Programming Tips Ensure only LED 1 is on in location...
IDS X64 Serial Programming
Complete guide for programming the serial on all X64 variants Serial/App Programming Requirements: Panel firmware: V2.80 or above GSM firmware: V4.51 or above OR E4.19 Draw power from Aux 12V, NOT from serial cable Programming: Loc 40: Ensure value 5 (CID)...
Paradox 1738 Programming
Very old panel - defaults are mostly wrong, use settings below Programming Locations Location 087 Enter 001 for daily test Location 110 Enter 0000 Location 131 LED 1 OFF (report disarm always) Dialer Options Location 135 (Tone dial) LED 3, 4, 5 ON All...
Paradox MG5050 and SP6000 Programming
Tested on Plus range version 1.30 Basic Programming Section 810 Select 44 for Contact ID Section 811 Account number for partition 1 Section 812 Account number for partition 2 Section 815 Enter 5555555 Section 817 Enter 5555555 Enabling the Dialer T...
Paradox Evo 192 Dialler
Programming sections for the Evo dialler Basic Dialler Setup Section 3036 Option 3 must be ON to enable the dialler Section 3061-3068 (Account Codes) 3061: Partition 1 account code 3062: Partition 2 account code Section 3070 (Format) Enter 4 x 5 for Cont...
Paradox Evo 848 Programming
Older Evo model programming Basic Programming Location 521 (Dialer options) LED 3, 4, 5, 6 must be ON All others OFF Location 550 (Format Contact ID) Enter 5555 Location 551 Enter [4-digit account code] Location 561 Enter [Phone number] Important Not...
Paradox Evo 192 Triggers
Configuration for direct trigger inputs using PGM outputs Prerequisites Before starting: Ensure jumper for PGMs is set to positive on panel motherboard If not set: Shut down panel Change jumper position Power up again Important: PGM1 stays negative - onl...
Paradox MG5050 DIALER + VERSION
Extended programming guide for MG5050 with dialer module Enable Dialer Section 800 Put numbers 4, 5, 6, 7, 8 OFF (this enables dialer) Basic Configuration Section 810 Enter 44 Section 811 Enter account number for telephone 1 Section 812 Enter account ...
Texecom 412/816/832 Programming
Standard Texecom panels with red serial cable Version Information Texecom 412/816: Known working app versions: V16.13 Texecom 832: Known working versions: v13, v14 (E) Note: Texecom Elite panels are NOT supported on app, but work with serial for CID Basi...
Texecom MiAlarm PANEL MODE
Configuration for MiAlarm compatibility Note: Texecom Elite panels are NOT supported on app, but work with serial for CID Programming Steps Enter Programming Mode Enter Installer Code Press Menu button Press 9 Location 76/0 Press location 76 Press subl...
Orisec Configuration
Orisec panels support both Tip/Ring and Com Port connections Orisec Tip/Ring Configuration Enter Installer Code Select Programming Menu → Tick/Enter Go to ARC Set up Phone Number: 555 5555 Account Number: As supplied by control room/software Protocol: Contac...
Risco Configuration
Complete programming guide for Risco panels Accessing Programming Press MENU BUTTON Enter INSTALLER CODE (Default: 1111) Navigate to "PROGRAMMING" → ENTER Navigate to "COMMUNICATION" → ENTER Monitoring Station Setup Navigate to "MONITORING STATION (MS)" → ...
miAlarm Troubleshooting
Common error codes and solutions for MiAlarm connectivity Device Busy Error Meaning: Unit is attempting to change mode Solutions: Wait 30-60 seconds and retry If persistent, power cycle the GSM unit Check if another user is accessing the system Verify no othe...
Common Issues & Solutions
Cross-panel troubleshooting guide Panel Not Sending Signals Check these first: Account code programmed correctly (4 digits, 6 digits with FF) Phone number is exactly 5555555 Contact ID enabled Dialer enabled (check specific panel locations) Sufficient dial a...
New Hire Training Outline
Draft — built fast, needs review/trimming. 1. The Products Overview of the Finmon product line: Comon, Telemon, Cenmon, Dualmon, mi8/64, miPanic What each product actually does and where it's used (which panel types, which install scenarios) Physical hardware...
1. Introduction
1.1 Purpose of This Guide This guide provides step-by-step instructions for using the Finmon Asset Management Portal. It is intended for existing and new Finmon clients. 1.2 System Overview The SIM Management Portal allows users to manage SIM card inventory, m...
2. Getting Started
2.1 System Requirements Before accessing the portal, ensure you have a Finmon portal profile (the same profile used at https://portal.finmon.co.za/). 2.2 Accessing the Portal To access the SIM Management Portal: Open a supported web browser. Navigate to: http...
3. SIM Inventory Management
3.1 Viewing the SIM Inventory The SIM Inventory displays all SIM cards associated with your account. To access it: Click SIMs in the navigation menu. The SIM inventory list will be displayed. SIM inventory navigation Inventory table columns 3.2 Searching a...