Paradox MG5050+ & SP6000+ Dialler Programming (done)
Extended programming guide for MG5050 with dialer module
Enable Dialer
Section 800
- Put numbers 4, 5, 6, 7, 8 OFF (this enables dialer)
Event Call Direction
Section 801
- Put all numbers OFF (Opening signal must always report)
Section 802
- Number 1 ON (Opening/Closing signals will report)
- Number 5 ON (Burglary Signals will report)
Section 803
- Number 1 ON (Tamper signals will report)
- Number 5 ON (Trouble signals will report)
Section 804
- Number 1 ON (Special codes will report)
Section 805
- Only number 2 ON
Basic Configuration
Section 810
- Enter 44
Section 811
- Enter account number for telephone 1
Section 812
- Enter account number for telephone 2
Section 815
- Enter telephone number of base station/Radio
- Press Enter after entering number
Additional Settings
Section 966 1, 2, 3, 4, 5, 6, Enter
Section 967 1, 2, 3, 4, 5, 6, Enter