Paradox MG5050, SP6000 & SP65 Serial Programming (done)
Tested on Plus range version 1.30
EnablingSerial theProgramming DialerNotes
Thethese statusare light on panel will be solid when dialling. If not dialling, check:MANDATORY:
Section 800910
Option 8 mustMust beOFFcleared Optionsusing4,sleep5,button6,(once7permust beONdigit)
SectionSec 802andtion 911
Options 1, 2, 5, 6 mustMust beONcleared using sleep button (once per digit)
Section 803
Options 1, 2, 5, 6 must beON
Section 805
Option 2 must beON
Dialler Programming
Section 810
Select44for Contact ID
Section 811
Account number for partition 1
Section 812
Account number for partition 2
Section 815
Enter5555555
Section 817
Enter5555555
Opening/Closing Reports
If closings work but not openings:
Section 801
All options must beOFF
Troubleshooting Tips
-
Panel won't send despite correct programming:
- Rarely, a default may be needed
- Power down, default, reprogram
-
Account number issues:
- MUST be entered at both 811 and 812
- With LED keypad: type account code twice at loc 811
PGM trigger issues:Jumper on motherboard above PGMs sets positive triggerOne model only sets one PGM as positive (not both)Paradox fixing in next PCB version
-
6500 Panel on serial:
- Does not send account code
- Only sends signal ONCE
Clear Event Buffer
For 5050 and 6000:
- Enter programming mode
- Press Stay key once
- Press Clear key once
- Power panel down
- Power up and send signals
For SP65: