General FINMON Programming
This page covers the essential programming requirements for all Finmon radio installations.
Required Programming Steps
The following must be programmed for the Finmon radio to work correctly:
-
Account Code
- Four digit code as required by control room
- Must be inserted in all required locations (some panels need it in multiple places)
- For six digit fields: program the four digits followed by FF (e.g., 1234FF)
-
Telephone Number
- Program '5555555' in both primary and secondary locations
- Must be exactly seven 5's
-
Communication Format
- Contact ID must be enabled
- This is the standard format for all installations
-
Dial Attempts
- Minimum of 6 attempts required
- Ensures reliable communication
-
Dial Timeout
- For kiss-on (if applicable): minimum 60 seconds
- If no timeout available, ensure attempts cover:
- 90 seconds for server send
- Additional 90 seconds for direct send
- SMS send time (if enabled)
- Note: SMS limit is 20 free messages per unit per month
-
Dialing Method
- Tone dialling must be enabled (usually default)
- Do not use pulse dialling
-
Special Requirements
- Forced dialling must be enabled (mostly for Caddx panels)
Important Notes
- Always verify all settings before leaving site
- Test communication after programming
- Document any deviations from standard programming
- Contact Finmon support if standard settings don't work