Skip to main content

Paradox MG5050 DIALER + VERSION

Extended programming guide for MG5050 with dialer module


Enable Dialer

Section 800

  • Put numbers 4, 5, 6, 7, 8 OFF (this enables dialer)

Basic Configuration

Section 810

  • Enter 44

Section 811

  • Enter account number for telephone 1

Section 812

  • Enter account number for telephone 2

Section 815

  • Enter telephone number of base station/Radio
  • Press Enter after entering number

Event Call Direction

Section 801

  • Put all numbers OFF (Opening signal must always report)

Section 802

  • Number 1 ON (Opening/Closing signals will report)
  • Number 5 ON (Burglary Signals will report)

Section 803

  • Number 1 ON (Tamper signals will report)
  • Number 5 ON (Trouble signals will report)

Section 804

  • Number 1 ON (Special codes will report)

Section 805

  • Only number 2 ON

Additional Settings

Section 966

  • Enter: 1, 2, 3, 4, 5, 6, Enter

Section 967

  • Enter: 1, 2, 3, 4, 5, 6, Enter


Verification

After programming:

  1. Check status LED for solid light when dialing
  2. Test each event type to ensure reporting
  3. Verify both telephone numbers if programmed
  4. Check event buffer for successful transmissions