Security Operations
Master the core security functions of your miAlarm app.
🔒 Arming & Disarming {#arm-disarm}
Arming Modes
🏠 Arm Home (Stay Mode)
- Perimeter zones active
- Interior zones bypassed
- Free movement inside
- Best for: When you're home
🏢 Arm Away
- All zones active
- Full protection enabled
- Exit delay provided
- Best for: Leaving property
🛏️ Arm Night
- Perimeter active
- Selected interior zones active
- Bedroom areas bypassed
- Best for: Overnight protection
How to Arm
Single Area:
- Open connected device
- Locate area card
- Tap desired arm button
- Confirm if prompted
- Exit within delay period
All Areas:
- Connected view → MORE
- Select Arm All
- System arms all ready areas
- Check status indicators
How to Disarm
Single Area:
- Tap the lock icon on armed area
- Enter code if required
- Area disarms immediately
All Areas:
- MORE → Disarm All
- Confirms all areas safe
- Instant disarm
Entry/Exit Delays
- Exit Delay: 45-60 seconds (configurable)
- Entry Delay: 30-45 seconds (configurable)
- Audio countdown on keypads
- Mobile shows timer
🎯 Zone Management {#zones}
Zone Types
Instant Zones
- Trigger immediately when armed
- No entry delay
- Used for: Windows, balconies
Delay Zones
- Allow entry time
- Must disarm within delay
- Used for: Entry doors
24-Hour Zones
- Always active
- Trigger even when disarmed
- Used for: Panic buttons, fire
Follower Zones
- Activate after entry zone
- Provide interior coverage
- Used for: Hallways, passages
Zone Status Indicators
Color | Status | Meaning |
---|---|---|
🟢 Green | Clear | Zone secure, no activity |
🔵 Blue | Bypassed | Zone disabled temporarily |
🔴 Red | Violated | Zone triggered/open |
🟠 Orange | Restored | Was violated, now clear |
Managing Zones
View All Zones:
- Tap grid icon (⋮⋮⋮)
- Heatmap shows all zones
- Filter by status/area
- Click for details
Edit Zone Info:
- Swipe right on zone
- Select "Edit Zone"
- Update:
- Zone name
- Location description
- Alert messages
- Save changes
🚨 Panic Features {#panic}
Panic Types
🔕 Silent Panic
- No audible alarm
- Discreet alert to monitoring
- Armed response dispatched
- Use when: Threat present
🏥 Medical Panic
- Medical response priority
- Ambulance dispatched
- Opens property access
- Use when: Medical emergency
🔥 Fire Panic
- Fire department alert
- All areas disarm
- Evacuation signal
- Use when: Fire detected
Activating Panic
From Home Screen:
- Enable silent panic in settings
- Panic button appears on home
- Quick 3-second press
From Device:
- Swipe device tile → Panic
- Or Connected view → PANIC
- Select panic type
- Hold center 3 seconds
From Any Screen:
- Hardware panic buttons
- Always active
- Works offline
After Panic Activation
- Signal sent immediately
- WhatsApp opens automatically
- Location pre-filled
- Send to emergency contact
- Armed response dispatched
Panic Best Practices
- Test monthly (test mode)
- Update emergency contacts
- Know your panic code
- Practice activation
- Brief family members
🔄 Bypassing Zones {#bypass}
What is Bypassing?
Temporarily disable specific zones while keeping others active.
When to Bypass
- Faulty sensor
- Maintenance work
- Leaving window open
- Pet in secured area
- Temporary access needed
How to Bypass
Method 1: Zone List
- Expand area card
- Find zone to bypass
- Toggle switch OFF
- Zone turns blue
Method 2: Heatmap
- Switch to heatmap view
- Tap zone tile
- Select "Bypass"
- Confirm action
Method 3: Quick Swipe
- In zone list
- Swipe right on zone
- Quick bypass toggle
Bypass Rules
- ⚠️ Reduces security
- 🔄 Resets on disarm (usually)
- 📝 Logged in history
- 🚫 Some zones cannot bypass
- ⏱️ May have time limits
Managing Bypassed Zones
View All Bypassed:
- Heatmap view
- Filter → "Bypassed"
- Shows blue zones only
Clear All Bypasses:
- Disarm area
- Re-arm without bypass
- Or manually unbypass each
Bypass Notifications:
- Alert when zones bypassed
- Reminder on arming
- Status in notifications
🛡️ Advanced Security Features
Duress Code
- Special code for emergencies
- Appears to disarm normally
- Secretly alerts monitoring
- Setup through installer
Auto-Arm/Disarm
- Schedule-based arming
- Automatic at set times
- Configure in panel settings
- Notifications on auto-events
Zone Testing
- Settings → Test Mode
- Walk through property
- Trigger each zone
- Verify detection
- Exit test mode
Event History
- View in notifications
- Filter by event type
- Export for records
- 90-day retention
🔐 Security Best Practices
Daily Operations
- ✅ Check zone status before arming
- ✅ Ensure all zones clear
- ✅ Use appropriate arm mode
- ✅ Test panic monthly
- ✅ Update emergency contacts
Maintenance
- 🔧 Test sensors monthly
- 🔧 Clean detectors regularly
- 🔧 Check battery levels
- 🔧 Update zone names
- 🔧 Review user access
Emergency Preparedness
- 📋 Family drill quarterly
- 📋 Know escape routes
- 📋 Practice panic activation
- 📋 Update contact info
- 📋 Test communication
⚡ Quick Reference
Arm/Disarm Shortcuts
- Quick Arm: Long press area
- Force Arm: Bypass and arm
- Instant Disarm: Panic + code
- All Areas: MORE menu
Status Colors
- 🟢 Green: Secure/Clear
- 🔵 Blue: Bypassed
- 🔴 Red: Alert/Violated
- 🟠 Orange: Restored
- ⚫ Gray: Offline
Response Times
- Panic: Immediate
- Alarm: 30-45 seconds
- Entry: Per zone setting
- Exit: Per area setting