Skip to main content

IDS805 Programming

IDS805 panels with grey serial cable on external serial connector


Basic Programming

Locations 43 to 46

  • Enter [Account code]

Location 47

  • Enter 6 (Contact ID)

Locations 48 to 54

  • Enter 5555555

Location 151

  • Default is 4 dial attempts
  • Enter 0 to disable the dialer
  • Leave at default for normal operation

Important Notes

  • Tone and force dialling are enabled by default
  • LTE GSM must be powered directly from battery
  • Do not power from panel auxiliary output

App Configuration

For mobile app connectivity:

Requirements:

  • App version v4.37 or latest vE4.xx
  • Serial Port must be set to Orisec/IDS805
  • Requires a VALID user code
  • ONLY POWER FROM THE SERIAL (no external power)

Troubleshooting

  • If no communication, verify power is from battery
  • Check serial cable is properly connected
  • Ensure account code is in all four locations (43-46)
  • Test with known working user code