Skip to main content

Wireless Devices

Requires Software version 6.64 (can be checked on the website)


Programming

Location 409 - Serial Port Type

  • Input a value of 2 for mi64 Wireless Devices

Location 200 - Add wireless device

  • Input zone number then [*] and hold down the LED on the wireless device until keypad beeps.

Location 454 - Remove wireless device

  • Enter zone number and then [*] to remove the device attached to that zone.

Location 0 - Remove ALL wireless device

  • Enter value of 6 and then [*] to remove all the wireless mi64 devices from the panel.

Notes

  • Devices are pinged every 17hours to confirm they are alive.
  • Devices are polled for battery life every 17hrs.
  • Tamper Switch is held down by the bracket on the passive not actually the back of the passive.