Wireless Devices
Requires Software version 6.64 (can be checked on the website)
Programming
Location 409 - Serial Port Type
- Input a value of 2 for iHorn Wireless Devices
Location 200 - Add wireless device
- Input zone number then [*] and hold down the LED on the wireless device until keypad beeps.
Location 454 - Remove wireless device
- Enter zone number and then [*] to remove the device attached to that zone.
Location 0 - Remove ALL wireless device
- Enter value of 6 and then [*] to remove all the wireless iHorn devices from the panel.
Notes
- Devices are pinged every 17hours to confirm they are alive.
- Devices are polled for battery life every 17hrs.
- Tamper Switch is held down by the bracket on the passive not actually the back of the passive.