Installation
Download and Installation iOS Installation Open the App Store on your iPhone or iPad Search for "miAlarm" Tap "Get" to download and install Wait for the installation to complete Android Installation Open Google Play Store Search for "miAlarm" Tap "Install"...
Account Registration
Creating Your Account First Launch When you open miAlarm for the first time, you'll see a welcome screen with two options: Login - For existing users Register - For new users Registration Process Select "Register" and provide the following information:...
Adding Devices
Adding Your First Device After successful registration, you'll be automatically logged in and prompted to add your first device. Option 1: Scan Device Barcode (Recommended) The fastest way to add your device: Tap "Add a Device" Allow camera access whe...
First Connection
Connecting to Your Device Once authorized, your device appears on the home screen showing: Device name Unit ID Connection status "Open" or "Connect" button Making Your First Connection Tap "Open" on your device tile If prompted, enter your 4-digit user cod...
Primary Device Configuration
Primary Device Configuration Understanding Primary Devices A primary device is your most frequently accessed alarm system, receiving: Priority connection allocation Prominent home screen placement Faster response times Setting Your Primary Device Method 1: H...
User Management
User Management Understanding User Roles The system supports multiple user types with varying permission levels: Master Users: Full administrative privileges Standard Users: Limited operational access User Administration (Master Users Only) Access device se...
Notification Configuration
Notification Configuration Comprehensive Alert Management Customize your notification preferences to receive only the information you need, when you need it. System-Wide Notifications Access sidebar menu Select "Notifications" View consolidated message center...
Emergency Contact Management
Emergency Contact Management Personal Emergency Contacts Configure trusted contacts for emergency situations: Add primary emergency contacts Test contact functionality regularly Official Emergency Services Customize official emergency numbers for your region...
Subscription Management
Subscription Management Account Tiers Free Account Connect up to 5 devices Access all core features No time restrictions Pro Subscription Connect up to 10 devices Advanced feature access Early access to new features Unlimited Subscription Connect an unlim...
Advanced Configuration
Advanced Configuration Device Synchronization Keep your device configuration current: Access device settings System retrieves latest configuration Updates include: Area definitions Zone configurations Smart action settings User permissions Operating Mode ...
Self-Service Tools
Self-Service Tools Account Management Password Reset Login screen → "Forgot Password" Enter registered email Check email for reset link Create new password Login with new credentials Update Contact Info In-app profile settings Edit email/phone number Verify...
New Page
miPanic Quick Reference Guide The miPanic is a versatile security system featuring 4 supervised zones and support for up to 64 user codes or remotes via a built-in receiver. 1. System Overview Zones: 4 Supervised zones (Requires $3.3k\Omega$ End-of-Line resi...
Finmon miPing Monitoring Service
What It Does The Finmon Ping Service continuously monitors the network connectivity of active alarm units. When a unit goes offline and stops responding, the service automatically raises a Loss of Polling alarm at the control room — just as if the unit had rep...
General FINMON Programming
This page covers the essential programming requirements for all Finmon radio installations. The Finmon GSM Communicator can work with ANY panel that speaks via Dialler with Contact ID. Required Programming Steps The following must be programmed for the Finmon...
Trigger Inputs Z1-4 on Transmitter
This page covers the configuration of direct trigger inputs on the Finmon transmitter. Default Configuration Factory Default Account Code: 9998 When a transmitter is connected to a panel via serial/dialler: The panel will automatically update the radio with ...
Caddx Standard Dialler Programming
Standard Caddx panels connected via Tip & Ring Location Programming Location 0 Segment 1 = 13 (force dial) Segment 2 = 15 (Tone dialling) Segment 3 to 9 = 5555555 (Tel number) Location 1 Segment 1 to 4 = [account code] Location 2 Enter 1 for Contact ID O...
Caddx NX Dialler Programming
Caddx NX (NX4 & NX8) series panels connected via Tip & Ring Location Programming Location 0 Segment 1 = 13 (force dial) Segment 2 = 15 (Tone dialling) Segment 3 to 9 = 5555555 (Tel number) Location 1 Segment 1 to 4 = [account code] Location 2 Enter 1 for...
DSC Standard PowerSeries Dialler Programming
Standard DSC PowerSeries prorgramming to get reporting working with Finmon GSM Communicators. Basic Programming Location 301 Enter 5555555 (tel number) LCD Keypad: Backspace and remove 'D', then enter 5's Location 303 Enter 5555555 (backup tel number) Loc...
DSC Neo Dialler Programming
DSC Neo panels with sub-locations (usually with LCD keypads) Accessing Programming Press *8 Enter Installer Code (default installer code is 5555) Location Programming Location 301 Sub 001: Remove 'D' and enter 555 5555 (Tel number 1) Sub 004: Remove 'E' (...