Skip to main content

Recently Updated Pages

IDS805 Programming

GSM Communicator Programming Manual Chapter 4: IDS Panels

IDS805 panels with grey serial cable on external serial connector Basic Programming Locations 43...

Updated 1 week ago by Jonathan Cox

Wireless Devices

Mi64

Requires Software version 6.64 (can be checked on the website) Programming Location 409 - Serial...

Updated 1 week ago by Jonathan Cox

Paradox MG5050 and SP6000 Programming

GSM Communicator Programming Manual Chapter 5: Paradox Panels

Tested on Plus range version 1.30 Basic Programming Section 810 Select 44 for Contact ID Secti...

Updated 4 weeks ago by Jonathan Cox

Texecom 412/816/832 Dialler Programming(done)

Finmon Cheat Sheet Rebuild Chapter 6: Texecom Panels

Version Information Texecom 412/816: Known working app versions: V16.13 Texecom 832: Known wo...

Updated 1 month ago by Jonathan Cox

Texecom 412/816/832 Serial Programming (done)

Finmon Cheat Sheet Rebuild Chapter 6: Texecom Panels

Standard Texecom panels with red serial cable Version Information Texecom 412/816: Known workin...

Updated 1 month ago by Jonathan Cox

Paradox MG5050+ & SP6000+ Dialler Programming (done)

Finmon Cheat Sheet Rebuild Chapter 5: Paradox Panels (done)

Extended programming guide for MG5050 with dialer module Enable Dialer Section 800 Put numbers ...

Updated 1 month ago by Jonathan Cox

Paradox Evo 192 Triggers (done)

Finmon Cheat Sheet Rebuild Chapter 5: Paradox Panels (done)

Configuration for direct trigger inputs using PGM outputs Prerequisites Before starting: Ensure...

Updated 1 month ago by Jonathan Cox

Paradox Evo 848 Dialler Programming(done)

Finmon Cheat Sheet Rebuild Chapter 5: Paradox Panels (done)

Older Evo model programming Basic Programming Location 521 (Dialer options) LED 3, 4, 5, 6 must...

Updated 1 month ago by Jonathan Cox

Paradox Evo 192 Dialler (done)

Finmon Cheat Sheet Rebuild Chapter 5: Paradox Panels (done)

Programming sections for the Evo dialler Basic Dialler Setup Section 3036 Option 3 must be ON t...

Updated 1 month ago by Jonathan Cox

Paradox MG5050, SP6000 & SP65 Dialler Programming (done)

Finmon Cheat Sheet Rebuild Chapter 5: Paradox Panels (done)

Tested on Plus range version 1.30 Enabling the Dialer The status light on panel will be solid wh...

Updated 1 month ago by Jonathan Cox

Paradox MG5050, SP6000 & SP65 Serial Programming (done)

Finmon Cheat Sheet Rebuild Chapter 5: Paradox Panels (done)

Tested on Plus range version 1.30 Serial Programming Notes these are MANDATORY: Section 910 Mus...

Updated 1 month ago by Jonathan Cox

Paradox 1738 Dialler Programming (done)

Finmon Cheat Sheet Rebuild Chapter 5: Paradox Panels (done)

Very old panel - defaults are mostly wrong, use settings below We dont support Serial on the 1738...

Updated 1 month ago by Jonathan Cox

HTML Installer Guide

Mi64

html version of mi64 Installer Manual mi64-Installer-Manual.html

Updated 2 months ago by Jonathan Cox

Finmon miPing Monitoring Service

miPing Service

What It Does The Finmon Ping Service continuously monitors the network connectivity of active ala...

Updated 3 months ago by Graeme

Texecom 412/816/832 Programming

GSM Communicator Programming Manual Chapter 6: Texecom Panels

Standard Texecom panels with red serial cable Version Information Texecom 412/816: Known workin...

Updated 3 months ago by Jonathan Cox

IDS X64 Dialler Programming

Finmon Cheat Sheet Rebuild Chapter 4: IDS Panels (done)

Complete guide for all X64 variants Basic Programming (All Versions) Location 41 Default settin...

Updated 3 months ago by Jonathan Cox

IDS X64 Serial Programming

Finmon Cheat Sheet Rebuild Chapter 4: IDS Panels (done)

Complete guide for programming the serial on all X64 variants Serial/App Programming Requirement...

Updated 3 months ago by Jonathan Cox

IDS806 Programming

GSM Communicator Programming Manual Chapter 4: IDS Panels

IDS806 panels with red serial cable Basic Programming Locations 43 to 46 Enter [Account code] ...

Updated 3 months ago by Jonathan Cox

IDS806 Serial Programming

Finmon Cheat Sheet Rebuild Chapter 4: IDS Panels (done)

IDS806 panels with red serial cable Basic Programming Locations 43 to 46 Enter [Account code] ...

Updated 3 months ago by Jonathan Cox

IDS806 Dialler Programming

Finmon Cheat Sheet Rebuild Chapter 4: IDS Panels (done)

Basic Dialler Programming Locations 43 to 46 Enter [Account code] Location 47 Enter 6 (Contact...

Updated 3 months ago by Jonathan Cox