Paradox MG5050 and SP6000 Programming
Tested up to Plus range version 1.30
Basic Programming
Section 810
- Select 44 for Contact ID
Section 811
- Account number for partition 1
Section 812
- Account number for partition 2
Section 815
- Enter 5555555
Section 817
- Enter 5555555
Enabling the Dialer
The status light on panel will be solid when dialling. If not dialling, check:
Section 800
- Option 8 must be OFF
- Options 4, 5, 6, 7 must be ON
Section 802
- Options 1, 2, 5, 6 must be ON
Section 803
- Options 1, 2, 5, 6 must be ON
Section 805
- Option 2 must be ON
Opening/Closing Reports
If closings work but not openings:
Section 801
- All options must be OFF
Babyware Programming
If using Babyware, these are MANDATORY:
Section 910
- Must be cleared using sleep button (once per digit)
Section 911
- Must be cleared using sleep button (once per digit)
Troubleshooting Tips
-
Panel won't send despite correct programming:
- Rarely, a default may be needed
- Power down, default, reprogram
-
Account number issues:
- MUST be entered at both 811 and 812
- With LED keypad: type account code twice at loc 811
-
PGM trigger issues:
- Jumper on motherboard above PGMs sets positive trigger
- One model only sets one PGM as positive (not both)
- Paradox fixing in next PCB version
-
6500 Panel on serial:
- Does not send account code
- Only sends signal ONCE
Clear Event Buffer
For 5050 and 6000:
- Enter programming mode
- Press Stay key once
- Press Clear key once
- Power panel down
- Power up and send signals
For SP65:
No comments to display