Trigger Inputs Z1-4 on Transmitter
This page covers the configuration of direct trigger inputs on the Finmon transmitter.
Default Configuration
Factory Default Account Code: 9998
When a transmitter is connected to a panel via serial/dialler:
- The panel will automatically update the radio with its account code on first signal
- If the account code is changed on the panel, it will update the radio again
Direct Connection to Z1-4
When connecting directly to trigger inputs (not through a panel):
-
Account Code Programming
- Must be set by dialling into the radio over the internet
- Use Finmon website: www.finmon.co.za
- REFER TO YOUR FINMON CONSULTANT OR CONTROL ROOM
-
Voltage Requirements
- The radio requires a positive 12v trip on any of the triggers.
- Ensure clean, stable 12v signal
Default Trigger Assignments
Input | Default Function |
---|---|
Z1 | Panic |
Z2 | Burglary |
Z3 | Open by user / Close by User |
Z4 | AC Failure |
Reprogramming Triggers
The trigger inputs can be reprogrammed for any Contact ID reporting code:
- Examples: supervisor on site, pump failure, temperature alarm
- Access required via Finmon website
- Contact Finmon support for custom programming
Wiring Notes
- Use appropriate gauge wire for 12v signals
- Keep wiring runs as short as practical
- Avoid running trigger wires parallel to AC power
- Use shielded cable in high-interference environments