Orisec Configuration

Orisec panels support both Tip/Ring and Com Port connections


Orisec Tip/Ring Configuration

  1. Enter Installer Code
  2. Select Programming Menu → Tick/Enter
  3. Go to ARC Set up
  4. Phone Number: 555 5555
  5. Account Number: As supplied by control room/software
  6. Protocol: Contact ID
  7. Dial Seq: 1
  8. Any issues with not sending - RESTART PANEL

Orisec Com Port Configuration

  1. Enter Installer Code
  2. Select Programming Menu → Tick/Enter
  3. Com Port Setup → Tick/Enter
  4. Select Com Port number 2
  5. Set mode to FINMON (Required for app)
  6. Hold Tick to go back
  7. Go to ARC Set up
  8. Phone Number: F555 5555 (Note the 'F' prefix)
  9. Account Number: As supplied by control room/software
  10. Protocol: Contact ID
  11. Dial Seq: 6
  12. Any issues with not sending - RESTART PANEL

App Configuration

Requirements:

  • App version must be v4.37
  • Serial Port must be set to Orisec/IDS
  • MUST be set to FINMON under Comm Port Setup

Critical Notes

IF YOU AREN'T GETTING SIGNALS OUT:

  • REBOOT THE PANEL
  • If serial port connected with panel powered up, it won't be detected
  • Always power cycle after connecting serial