Skip to main content

IDS X64 Programming

Complete guide for all X64 variants


Basic Programming (All Versions)

Location 41

  • Default setting usually fine
  • Set to 5 for Contact ID on Telephone Number 1

Location 46

  • Subloc 1 (LED 1): ON for Tone dialling
  • Subloc 2 (LED 2): OFF
  • Subloc 3 (LED 3): OFF

Location 47

  • Set to 6

Location 51

  • Enter 5555555 (seven 5's)

Location 61-68 (Account Codes)

  • Loc 61: Partition 1 account code (4 digits)
  • Loc 62: Partition 2 account code
  • Loc 63-68: Partitions 3-8 account codes

Location 71 (72 = P2 -> 78 = P8)

  • Serial account code (same as partition account code)

Location 196

  • Must be 000000

Location 501-564

  • Option 3 must be set to Yes

Enable User Code Bypassing Hold [ * ] → beep → [MASTER CODE] [ * ] [ 1 ] [ 0 ] [ * ] [USER CODE] [ * ] [BITMAP] [ * ] [ # ]

Bitmap(Option 8) Zone Bypass Enable MUST be set to Yes


Open/Close Reporting by User

For X64 Older than 2017

Programming Sequence: Hold [ * ] → beep → [ MASTER CODE ] [ * ] [ 1 ] [ 4 ] [ * ] [ USER CODE ] [ * ] [ BITMAP ] [ * ] [ # ]

Enable User Reporting Codes:

Subloc/LED Default Action
1 OFF Set ON to enable close reporting
2 OFF Set ON to enable stay close reporting
3 OFF Set ON to enable open reporting
4 OFF Set ON to enable siren cancel reporting

Important: Must be repeated for EACH user requiring open/close reporting!

For X64 New (2017 onwards)
  1. Enter Installer Mode
  2. Go to Partition Arm Options (Locations 211-218)
  3. Enable option 16 (Open/Closing User Reporting), this option is global for all users in the partition.

Arm Without User Code Reporting

For quick-arm and key-switch arming:

Locations 581-588 (Split Reporting Data)

  • Subloc 7: Set ON to enable "Armed without user code" reporting
  • Location 581 for Partition 1
  • Location 582 for Partition 2
  • Locations 583-588 for Partitions 3-8

Serial/App Programming

Requirements:

  • Panel firmware: V2.80 or above
  • GSM firmware: V4.51 or above
  • Draw power from Aux 12V, NOT from serial cable

Programming:

  • Loc 40: Ensure value 5 (CID) is programmed
  • Loc 61: Account code required
  • Loc 196: Must be 000000

24V Version Additional:

  • Loc 71: Account code required

Troubleshooting

  • If you can connect but get Bypassed zones and are unable to do anything: Check Loc 196 = 000000
  • After changing Loc 196: Remove panel from app and re-add
  • Cannot control panel: Verify user code
  • Connection issues: Check power source (must be Aux 12V)