Paradox Evo 192 Dialler
Programming sections for the Evo dialler
Basic Dialler Setup
Section 3036
- Option 3 must be ON to enable the dialler
Section 3061-3068 (Account Codes)
- 3061: Partition 1 account code
- 3062: Partition 2 account code
Section 3070 (Format)
- Enter 4 x 5 for Contact ID
Section 3071 (Telephone Number)
- Enter 5555555
Event Reporting Configuration
Sections 3127 to 3829
- Check partition options for event call directions
- These sections tell the panel what events need to be reported
Section 4031
- Enable all reporting codes for Contact ID
Important Programming Tips
After all programming:
- REBOOT the panel - Critical step!
- Disable the dialer module
- Re-enable the dialer module, This clears the module for correct dialling.
Account Code Rules:
- NEVER use account codes starting with "0" (e.g., 0001)
- Use 1001 instead
- Can use hex A: 1AA1 (press "stay" button for hex A)
Troubleshooting
- If panel won't communicate after programming, always reboot
- Disable/re-enable dialer module if issues persist
No comments to display